The Decline of Lumbar Artificial Disc Replacement
Article Information
Tony Eskandar1, Zubair Ahmed1, Jeremy Pan1, Devendra K. Agrawal1*
1Department of Translational Research, College of Osteopathic Medicine of the Pacific, Western University of Health Sciences, Pomona CA 91766, USA
*Corresponding Author: Devendra K. Agrawal, MSc, PhD (Biochem), PhD (Med Sci), MBA, MS (ITM), FAAAAI, FAHA, FAPS, FIACS, Professor and Director, Department of Translational Research, Western University of Health Sciences, 309 E. Second Street, Pomona, California 91766, USA
Received: 08 August 2024; Accepted: 19 August 2024; Published: 22 August 2024
Citation:
Tony Eskandar, Zubair Ahmed, Jeremy Pan, Devendra K. Agrawal. The Decline of Lumbar Artificial Disc Replacement, Journal of Spine Research and Surgery. 6 (2024): 86-92.
View / Download Pdf Share at FacebookAbstract
Lower back pain associated with degenerative disc disease is a common occurrence, with many surgical treatments targeting the degenerated disc to relieve symptoms. Current surgical options for degenerative disc disease primarily consist of a discectomy followed by either spinal fusion or artificial disc replacement, with the former being increasingly more common in the lumbar region despite the risk of adjacent segment disease. Though artificial disc replacement aims to provide an increase in range of motion and decreases risk of adjacent segment disease, surgeons are increasingly opting for spinal fusion in the lumbar region. This review investigates underlying factors that may be contributing to this trend by assessing lumbar artificial disc replacement selection criteria, clinical outcomes, surgical technique, complications, revision burden, and overall cost. While these factors had some role in the physician’s decision, ultimately the narrow selection criteria and lack of cost reimbursement by insurance has primarily led to the decline in lumbar artificial disc replacement.
Keywords
Adjacent segment disease; Artificial disk replacement; Degenerative disc disorder; Lower back pain; Lumbar disc arthroplasty; Spinal fusion
Article Details
Introduction
Lower back pain comprises the greatest burden of years lived with disability globally, with cases increasing by roughly 60% from 1990 to 2020 and another 36.4% increase projected by 2050 [7]. Lower back pain is associated with signs of degenerative disc disorder indicated by the presence of osteophytes, endplate sclerosis and disc space narrowing on radiologic imaging [8, 23, 46]. It is important to note that in the current literature, no main case definition for degenerative disc disorder persists, and the associated findings can vary between the cervical and lumbar region [1]. While degenerative disc disorder does not always cause lower back pain and presents frequently among asymptomatic individuals, symptomatic degenerative disc disorder affects approximately 5.5% of individuals worldwide [39, 43].
While physical therapy, anti-inflammatory medications, and other conservative treatments for degenerative disc disorder may help manage lower back pain, in some patients, discogenic pain can be drastic enough to affect activities of daily living, leading to exacerbation of symptoms and worse outcomes [14]. In cases where nonoperative, conservative treatments fail to show improvement, discectomy and vertebral arthrodesis, also known as spinal fusion (FUS), have traditionally been the gold standard in the surgical management of degenerative disc disorder in the cervical and lumbar spine regions. This procedure involves removing the degenerated disc, replacing it with an interbody spacer, and ultimately fusing them together as a unit at the affected level with instrumentation affixed to the adjacent vertebrae using screws [11, 16, 24]. Since the vertebral disc aids in facilitating the range of motion (ROM) of vertebrae and acts as a mechanical shock absorber, FUS limits range of motion and mobility, and diverts spinal load to adjacent vertebrae [30, 52]. This increases the risk of developing adjacent segment disease (ASD), among other known complications such as pseudoarthrosis and instrumentation failure [31,54]. ASD can then lead to resurgence of symptoms as degeneration progresses to adjacent vertebrae and would eventually require further surgical intervention.
While spinal fusion affixes vertebrae and limits range of motion, artificial disc replacement (ADR) aims to restore disc height, lordotic structure, and biomechanical motion to that of an intact intervertebral disc, ultimately rebalancing the spine [25, 40, 45, 57]. This restoration of the range of motion and mobility is associated with a reduced risk of ASD; nonetheless, there remains the risk of heterotopic ossification, facet joint degradation (FJD), and implant migration are among other complications reported [20, 50, 56]. With decreased ASD and other benefits in consideration, upon FDA approval of spinal disc arthroplasty on October 26, 2004, ADR became the popular alternative to FUS for eligible surgical candidates [10].
While ADR seems to pose an advantage in preserving adjacent level degeneration in comparison to FUS, there has been a negative trend in the use of ADR in the lumbar region as compared with a rising trend within the cervical region. The rate of lumbar ADR (LADR) decreased 85% from 2005 to 2017 while the rate of cervical ADR increased approximately 800% in the same period based on the National Inpatient Sample database [28]. While this data is limited to inpatient cases, there still appears to be a stark contrast in the rate of ADR between the two spinal regions, considering that LADR was approved by the FDA first [10, 28].
Literature Search Methods
An exhaustive literature search was performed, specifically targeting artificial disc replacement in the lumbar region of the spine. The primary search of the relevant literature was conducted using the key words ‘lumbar artificial disc replacement' and ‘lumbar disc arthroplasty'. All data were extracted from article texts, tables, and figures.
This review aims to investigate and discuss potential factors influencing the decreasing national trend in LADR by primarily examining cross-sectional analyses, case reports, and case series that assess LADR in comparison to discectomy and arthrodesis. Assessment of selection criteria, clinical outcomes, surgical technique, complications, revision burden, and overall cost with LADR are the basis of this review to investigate the potential factors influencing this recent negative trend.
Selection Criteria for Lumbar Artificial Disc Replacement
While there is much overlap between candidacy for lumbar artificial disc replacement (LADR) and spinal fusion (FUS) for treating lower back pain correlated with degenerative disc disorder, LADR has shown to have a more specific use case. Ideal patient demographics varied across the literature, but several studies appear to indicate a nonsmoking, nonobese patient in range of 18 - 60 years old [4, 12, 27, 47]. LADR is indicated for symptomatic degenerative disc disorder or lumbar spondylosis, but recently been expanded to include patients with prior surgeries microdiscectomy and prior fusions [26, 45]. Patients must have experienced and failed to improve following at least 6 months of conservative, nonoperative treatments such as physical therapy, which is standard across both FUS and LADR [16, 45]. Radiographic findings should include evidence of nucleus pulposus herniation, significant disc height narrowing, minimal facet degeneration, and thickened annulus fibrosis with osteophytes indicating osteoarthritis following both magnetic resonance imaging and computer topography scan [26, 36, 38].
Since LADR targets the intervertebral disc and restores motion, it is ideal for patients with primarily discogenic pain and adequate bone quality for implant fixation and without motion impairments or spinal instability [44, 45, 53]. Figure 1 shows the contraindications specific to LADR include ankylosing spondylitis, facet degeneration, neuroforaminal stenosis (except when restoring neuroforaminal height), osteoporosis, radiculopathy, spondylosis, scoliosis, spinal fractures, and spondylolisthesis [4, 17, 26, 45, 53].
Figure 1: The figure depicts an illustration of contraindications to lumbar artificial disc replacement (LADR) on the right being compared to normal conditions on the left side of the image. This graphic includes ankylosing spondylitis, facet joint degradation (FJD), osteoporosis, spinal fractures, scoliosis, and radiculopathy, such as with neuroforaminal stenosis.
Clinical Outcomes
The most utilized measure for clinical outcomes in spinal disorders and treatment are the Oswestry Disability Index and Visual Analogue Scale [9]. The Oswestry Disability Index is a self-administered questionnaire with several sections pertaining to activities of daily living and a scale of disability from 0 to 5, with 5 being the greatest disability [3, 9, 27]. The Visual Analogue Scale is a self-administered scale with a 100mm, horizontal or vertical line separating two opposing verbal descriptors regarding pain status and recorded as the marked distance along the line out of 100mm [5, 18, 48]. Along with range of motion, Oswestry Disability Index and Visual Analogue Scale was assessed in most FDA investigational device exemption studies of the LADR implant types.
The devices approved by the FDA for the lumbar region include the INMOTION® (formerly Charité ®), activL ®, and Prodisc® L, with only the Prodisc-L being approved for treating two contiguous spinal levels in the L3-S1 region as of April 10, 2020 [10]. A review assessing the investigational device exemption studies comparing the Prodisc-L single-level and Charité implants to fusion each resulted in clinical success of roughly 63.5%, despite having a stringent clinical success definition requiring a 50% improvement in Oswestry Disability Index [35]. Further findings indicated that most patients achieved their 24-month results by the 3rd month post-operatively, or otherwise likely predicted failure [35]. Consistent with previous 2- and 5-year randomized trials, Radcliff et al. 2021 reported 7-year findings comparing activL and Prodisc-L implants. While both implants lead to significantly improved Visual Analogue Scale and Oswestry Disability Index, the activL implant had improved range of motion preservation and a better safety profile compared to the Prodisc-L implant [37]. It is also important to note that the inclusion and exclusion criteria for the 7-year trial were consistent with the previously mentioned ideal patient criteria.
Surgical Technique
The typical surgical approach for LADR is via an anterior midline retroperitoneal incision just as in an anterior lumbar interbody fusion. A complete discectomy and mobilization are performed, with optional removal of the posterior longitudinal ligament [31, 58]. The endplate is prepared with measurements reconfirmed before placement, inserted firmly via distraction of the disc space, and then the implant is assembled in the disc space [58]. Final positioning is adjusted and verified via fluoroscopy to ensure placement is in the center and avoid sagittal imbalance from placement being too anterior [15, 31, 58]. Final reconstruction of the anterior longitudinal ligament is now recommended to reduce the risk of FJD [29, 35]. In the case of implant failure and revision, most cases across several studies opted for removal of the implant and conversion to FUS [19, 34, 55].
Complications and Revision Burden
The main complication of concern with LADR is facet joint degradation, accounting for up to 50% of failure cases in one study [35, 41]. Factors that increased risk of facet joint degradation included improper placement of the implant and removing the anterior longitudinal ligament (ALL), which both lead to sagittal imbalance [15, 22, 35, 50]. As depicted in Figure 2A, an anterior shift of the center of rotation of the LADR implant leads to increased ligament and facet forces, increasing the risk of complications such as facet degeneration [15]. Likewise, as illustrated in Figure 2B, removal of the ALL would shift the balance of load onto the posterior aspect of the spine, where the facet joints reside [35]. In another prospective trial with the Prodisc-L implant, while Oswestry Disability Index, Visual Analogue Scale, and range of motion showed improvement in most patients, facet joint degradation developed in others and ultimately led to decreased range of motion [50]. Ultimately, positioning of the LADR implant and the ALL appear to play a major role in development of facet joint degradation and could lead to a decrease in the range of motion.
While proper surgical technique and certain changes in approach can help improve success rate and decrease future LADR complications, patients who have already undergone the surgery may eventually need revisions. Revision burden for LADR rose by 400% from 2005 to 2013, owing to an initial enthusiasm with the relatively new procedure but also a significant spike in revisions in 2012 [42]. Another study assessing the Nationwide Inpatient Sample found revision burden higher for LADR in comparison to spinal fusion, yet within the burden range of hip and knee replacement surgeries that are considered cost-effective [2, 21]. While there is room for improvement regarding LADR revision burden, the more recent findings influencing selection criteria and surgical technique may begin to decrease this burden.
Figure 2: The figure depicts an illustration of the see-saw-like load distribution that occurs with shifting the position of the lumbar artificial disc replacement (LADR) implant or removal of the anterior longitudinal ligament (ALL) as described in Han et al., 2013. (A) An exaggerated anterior shift leads to increased load on the facet and ALL depicted by the enlarged red arrows, while the green arrow depicts the force from the load on the vertebral body. (B) Removal of the ALL diminishes the tension depicted by the green arrow and leads to increased facet load on the opposing side of the spinal column.
Overall Cost
Several cost analyses have been conducted comparing LADR to different spinal fusion approaches with 2-year follow-ups and all clinical outcomes considered normalized. Owing to decreased operating room times and hospital stays, LADR is typically equal to or less than the cost of anterior approach fusion surgeries, and significantly less than posterior or multiple approach fusion surgery [59, 32, 33, 51]. Another factor that elevates cost in FUS beyond the 2-year follow-up period would be a higher reoperation rate [13]. Though overall costs are lower for LADR, most insurance companies in the United States frequently deny coverage for disc replacements fearing delayed complications and revisions [42]. This costs physicians and hospitals more time as they appeal for insurance reimbursements that ultimately pay out less than spinal fusion surgery reimbursements [33, 49]. These reimbursement issues are discouraging factors that have a negative impact healthcare policies and physician decisions, which further limit the use and development of LADR.
Conclusion
While many elements play a role in the decision making of surgeons when choosing one modality over another, a few major factors alone can explain the drastic decline in lumbar artificial disc replacement compared to the rise in spinal fusion and cervical artificial disc replacement. Regarding patient selection, presence of many contraindications of lumbar artificial disc replacement, and specific patient criteria can limit candidacy to as low as 5% of a surgeon’s practice [6]. Minor improvements in surgical technique are decreasing the risk of facet joint degradation and implant failure, leading to significant clinical outcomes. With lumbar artificial disc replacement being a relatively new procedure in comparison to spinal fusion, an initial rise in revision burden was bound to occur until surgical technique and selection criteria were revised and improved. Although overall cost is lower in comparison to spinal fusion, the lack of reimbursement from insurance companies makes the financial burden a major hurdle for both the patient and provider. Though lumbar artificial disc replacement will never return to its initial prevalence, more long-term, prospective cohort studies and cost-analyses should be done to further highlight the efficacy of lumbar artificial disc replacements, expand the patient candidacy, and encourage insurance policy changes to improve the rate of reimbursement.
Funding:
The research work of DKA is supported by the R01 HL144125 and R01 HL147662 grants from the National Institutes of Health, USA. The contents of this article are solely the responsibility of the authors and do not necessarily represent the official views of the National Institutes of Health.
Competing interests:
All authors have read the manuscript and declare no conflict of interest. No writing assistance was utilized in the production of this manuscript.
Consent for publication:
All authors have read the manuscript and consented for publication.
References
- Battie, M. C., Joshi, A. B., Gibbons, L. E., & Group, I. D. S. P. Degenerative Disc Disease: What is in a Name? Spine (Phila Pa 1976), 44 (2019): 1523-1529.
- Beatty, S. We Need to Talk about Lumbar Total Disc Replacement. Int J Spine Surg, 12 (2018): 201-240.
- Brodke, D. S., Goz, V., Lawrence, B. D., et al. Oswestry Disability Index: a psychometric analysis with 1,610 patients. Spine J, 17 (2017): 321-327.
- Buttner-Janz, K., Guyer, R. D., & Ohnmeiss, D. D. Indications for lumbar total disc replacement: selecting the right patient with the right indication for the right total disc. Int J Spine Surg, (2014): 8.
- Chiarotto, A., Maxwell, L. J., Ostelo, R. W., et al. Measurement Properties of Visual Analogue Scale, Numeric Rating Scale, and Pain Severity Subscale of the Brief Pain Inventory in Patients With Low Back Pain: A Systematic Review. J Pain, 20 (2019): 245-263.
- Chin, K. R. Epidemiology of indications and contraindications to total disc replacement in an academic practice. Spine J, 7 (2007): 392-398.
- Collaborators, G. B. D. L. B. P. (2023). Global, regional, and national burden of low back pain, 1990-2020, its attributable risk factors, and projections to 2050: a systematic analysis of the Global Burden of Disease Study 2021. Lancet Rheumatol, 5 (2023): e316-e329.
- de Schepper, E. I., Damen, J., van Meurs, J. B., et al. The association between lumbar disc degeneration and low back pain: the influence of age, gender, and individual radiographic features. Spine (Phila Pa 1976), 35(5), 531-536. Fairbank, J. C. (2014). Oswestry disability index. J Neurosurg Spine, 20 (2010): 239-241.
- Fairbank, J. C., & Pynsent, P. B. (2000). The Oswestry Disability Index. Spine (Phila Pa 1976), 2 5 (2000): 2940-2952
- Fiani, B., Nanney, J. M., Villait, A., et al. Investigational Research: Timeline, Trials, and Future Directions of Spinal Disc Arthroplasty. Cureus, 13 (2021): e16739.
- Foley, K. T., Holly, L. T., & Schwender, J. D. Minimally invasive lumbar fusion. Spine (Phila Pa 1976), 28 (2003): S26-35.
- Foreman, M., Patel, A., Nguyen, A., et al. Management Considerations for Total Intervertebral Disc Replacement. World Neurosurg, 181 (2024): 125-136.
- Fritzell, P., Berg, S., Borgstrom, F., et al. Cost effectiveness of disc prosthesis versus lumbar fusion in patients with chronic low back pain: randomized controlled trial with 2-year follow-up. Eur Spine J, 20 (2011): 1001-1011.
- Fritzell, P., Hagg, O., Wessberg, P., Nordwall, A., & Swedish Lumbar Spine Study, G. Chronic low back pain and fusion: a comparison of three surgical techniques: a prospective multicenter randomized study from the Swedish lumbar spine study group. Spine (Phila Pa 1976), 27 (2002), 1131-1141.
- Han, K. S., Kim, K., Park, W. M., et al. Effect of centers of rotation on spinal loads and muscle forces in total disk replacement of lumbar spine. Proc Inst Mech Eng H, 227 (2013), 543-550.
- Hanley, E. N., Jr., & David, S. M. Lumbar arthrodesis for the treatment of back pain. J Bone Joint Surg Am, 81 (1999): 716-730.
- Huang, R. C., Lim, M. R., Girardi, F. P., & Cammisa, F. P., Jr. The prevalence of contraindications to total disc replacement in a cohort of lumbar surgical patients. Spine (Phila Pa 1976), 29 (2004): 2538-2541.
- Huskisson, E. C. Measurement of pain. Lancet 2 (1974): 1127-1131.
- Kitzen, J., Vercoulen, T. F. G., van Kuijk, S. M. J., et al. Long-term clinical outcome of two revision strategies for failed total disc replacements. Eur Spine J, 29 (2020): 1536-1543.
- Koutsogiannis, P., Khan, S., Phillips, F., et al. A cross-sectional analysis of 284 complications for lumbar disc replacements from medical device reports maintained by the United States Food and Drug Administration. Spine J, 22 (2022): 278-285.
- Kurtz, S. M., Lau, E., Ianuzzi, A., et al. National revision burden for lumbar total disc replacement in the United States: epidemiologic and economic perspectives. Spine (Phila Pa 1976), 35 (2010): 690-696.
- Le Huec, J., Basso, Y., Mathews, H., et al. The effect of single-level, total disc arthroplasty on sagittal balance parameters: a prospective study. Eur Spine J, 14 (2005): 480-486.
- Luoma, K., Riihimaki, H., Luukkonen, R., et al. Low back pain in relation to lumbar disc degeneration. Spine (Phila Pa 1976), 25 (2000): 487- 492.
- Lykissas, M. G., & Aichmair, A. Current concepts on spinal arthrodesis in degenerative disorders of the lumbar spine. World J Clin Cases, 1 (2013): 4-12.
- Mayer, H. M. Total lumbar disc replacement. J Bone Joint Surg Br, 87 (2005): 1029-1037.
- McAfee, P. C. The indications for lumbar and cervical disc replacement. Spine J, 4 (2004), 177S-181S.
- Mehra, A., Baker, D., Disney, S., et al. Oswestry Disability Index scoring made easy. Ann R Coll Surg Engl, 90 (2008): 497-499.
- Mills, E. S., Shelby, T., Bouz, G. J., et al. A Decreasing National Trend in Lumbar Disc Arthroplasty. Global Spine J, 13 (2023): 2271-2277.
- Mobbs, R. J., Li, J. X. J., & Phan, K. Anterior Longitudinal Ligament Reconstruction to Reduce Hypermobility of Cervical and Lumbar Disc Arthroplasty. Asian Spine J, 11 (2017): 943-950.
- Mu, X., Wei, J., A, J., et al. The short-term efficacy and safety of artificial total disc replacement for selected patients with lumbar degenerative disc disease compared with anterior lumbar interbody fusion: A systematic review and meta-analysis. PLoS One, 13 (2018): e0209660.
- Othman, Y. A., Verma, R., & Qureshi, S. A. Artificial disc replacement in spine surgery. Ann Transl Med, 7 (2019): S170.
- Parkinson, B., Goodall, S., & Thavaneswaran, P. Cost-effectiveness of lumbar artificial intervertebral disc replacement: driven by the choice of comparator. ANZ J Surg, 83 (2013): 669-675.
- Patel, V. V., Estes, S., Lindley, E. M., et al. Lumbar spinal fusion versus anterior lumbar disc replacement: the financial implications. J Spinal Disord Tech, 21 (2008): 473-476.
- Perfetti, D. C., Galina, J. M., Derman, P. B., et al. Risk factors for reoperation after lumbar total disc replacement at short-, mid-, and longterm follow-up. Spine J, 21 (2021): 1110-1117.
- Pettine, K., Ryu, R., & Techy, F. (2017). Why Lumbar Artificial Disk Replacements (LADRs) Fail. Clin Spine Surg, 30 (2017): E743-E747.
- Pye, S. R., Reid, D. M., Smith, R., et al. Radiographic features of lumbar disc degeneration and self-reported back pain. J Rheumatol, 31 (2004): 753-758.
- Radcliff, K., Zigler, J., Braxton, E., et al. Final Long-Term Reporting from a Randomized Controlled IDE Trial for Lumbar Artificial Discs in Single-Level Degenerative Disc Disease: 7-Year Results. Int J Spine Surg 15 (2021): 612-632.
- Rahyussalim, A. J., Zufar, M. L. L., Kurniawati, T. Significance of the Association between Disc Degeneration Changes on Imaging and Low Back Pain: A Review Article. Asian Spine J, 14 (2020): 245-257.
- Ravindra, V. M., Senglaub, S. S., Rattani, A., et al. Degenerative Lumbar Spine Disease: Estimating Global Incidence and Worldwide Volume. Global Spine J, 8 (2018): 784-794.
- Ren, C., Song, Y., Liu, L., et al. Adjacent segment degeneration and disease after lumbar fusion compared with motion-preserving procedures: a meta-analysis. Eur J Orthop Surg Traumatol, 24 (2014): S245-253.
- Rosen, C., Kiester, P. D., & Lee, T. Q. Lumbar disk replacement failures: review of 29 patients and rationale for revision. Orthopedics, 32 (2009).
- Saifi, C., Cazzulino, A., Park, C., et al. National Trends for Primary and Revision Lumbar Disc Arthroplasty Throughout the United States. Global Spine J, 8 (2018): 172-177.
- Salo, S., Hurri, H., Rikkonen, T., et al. Association between severe lumbar disc degeneration and self-reported occupational physical loading. J Occup Health, 64 (2022): e12316.
- Salzmann, S. N., Plais, N., Shue, J., et al. Lumbar disc replacement surgerysuccesses and obstacles to widespread adoption. Curr Rev Musculoskelet Med, 10 (2017): 153-159.
- Sandhu, F. A., Dowlati, E., & Garica, R. Lumbar Arthroplasty: Past, Present, and Future. Neurosurgery, 86 (2020): 155-169.
- Scarcia, L., Pileggi, M., Camilli, A., et al. Degenerative Disc Disease of the Spine: From Anatomy to Pathophysiology and Radiological Appearance, with Morphological and Functional Considerations. J Pers Med, 12 (2022).
- Schoenfeld, A. J., Carey, P. A., Cleveland, A. W., et al. Patient factors, comorbidities, and surgical characteristics that increase mortality and complication risk after spinal arthrodesis: a prognostic study based on 5,887 patients. Spine J, 13 (2013): 1171-1179.
- Shafshak, T. S., & Elnemr, R. The Visual Analogue Scale Versus Numerical Rating Scale in Measuring Pain Severity and Predicting Disability in Low Back Pain. J Clin Rheumatol, 27 (2021): 282-285.
- Siepe, C. J., Heider, F., Wiechert, K., et al. Mid- to long-term results of total lumbar disc replacement: a prospective analysis with 5- to 10-year followup. Spine J, 14 (2014): 1417-1431.
- Siepe, C. J., Zelenkov, P., Sauri-Barraza, J. C., et al. The fate of facet joint and adjacent level disc degeneration following total lumbar disc replacement: a prospective clinical, X-ray, and magnetic resonance imaging investigation. Spine (Phila Pa 1976), 35 (2010): 1991-2003.
- Stubig, T., Ahmed, M., Ghasemi, A., et al. Total Disc Replacement Versus Anterior-Posterior Interbody Fusion in the Lumbar Spine and Lumbosacral Junction: A Cost Analysis. Global Spine J, 8 (2018): 129-136.
- Tobert, D. G., Antoci, V., Patel, S. P., et al. Adjacent Segment Disease in the Cervical and Lumbar Spine. Clin Spine Surg, 30 (2017): 94-101.
- Uschold, T. D., Fusco, D., Germain, R., et al. Cervical and lumbar spinal arthroplasty: clinical review. AJNR Am J Neuroradiol, 33 (2012): 1631-1641.
- Virk, S. S., Niedermeier, S., Yu, E., et al. Adjacent segment disease. Orthopedics, 37 (2014): 547-555.
- Wagner, W. H., Regan, J. J., Leary, S. P., et al. Access strategies for revision or explantation of the Charite lumbar artificial disc replacement. J Vasc Surg, 44 (2006): 1266-1272.
- Wellington, I. J., Kia, C., Coskun, E., Torre, B. B., et al. Cervical and Lumbar Disc Arthroplasty: A Review of Current Implant Design and Outcomes. Bioengineering (Basel), 9 (2022).
- Yue, J. J., Garcia, R., Blumenthal, S., et al. Five-year Results of a Randomized Controlled Trial for Lumbar Artificial Discs in Single-level Degenerative Disc Disease. Spine (Phila Pa 1976), 44 (2019): 1685-1696.
- Yue, J. J., Garcia, R., Jr., & Miller, L. E. The activL((R)) Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain. Med Devices (Auckl), 9 (2016): 75-84.
- Guyer, R. D., Tromanhauser, S. G., & Regan, J. J. An economic model of one-level lumbar arthroplasty versus fusion. Spine J, 7 (2007): 558-562.