The Elimination of the Return line from the HVAC systems due to COVID-19

Abdullah Abbas Kendoush

Dept. of Nuclear Engineering Technology, Augusta Technical College, Augusta, GA 30906, USA

*Corresponding author: Abdullah Abbas Kendoush, Dept. of Nuclear Engineering Technology, Augusta Technical College, Augusta, GA 30906, USA

Received: 01 May 2025; Accepted: 08 May 2025; Published: 09 May 2025

Article Information

Citation: Abdullah Abbas Kendoush. The Elimination of the Return line from the HVAC systems due to COVID-19. Archives of Microbiology and Immunology. 9 (2025): 163-164.

DOI: 10.26502/ami.936500219

View / Download Pdf Share at Facebook

Abstract

Due to the spread of the deadly COVID-19 virus in the US and around the world, the authors propose the elimination of the return line from the HVAC (Heating, Ventilation, and Air conditioning) systems [1], simply by closing the return air damper (RAD) shown Figure 1 that represents a single zone HVAC system. The idea of closing the RAD may be applied to other Design systems such as variable air volume, terminal air reheat, dual duct flow, . . .etc.

Keywords

COVID-19, return air damper (RAD), HVAC

Article Details

Case Presentation

Due to the spread of the deadly COVID-19 virus in the US and around the world, the authors propose the elimination of the return line from the HVAC (Heating, Ventilation, and Air conditioning) systems [1], simply by closing the return air damper (RAD) shown Figure 1 that represents a single zone HVAC system. The idea of closing the RAD may be applied to other Design systems such as variable air volume, terminal air reheat, dual duct flow, . . .etc.

It should be noted, that the presence of filters in the HVAC systems, is not capable of preventing the transfer of the COVID-19 virus through theses filters. Employing efficient filters like MERV 13 that filter 0.3-micron size virus [2] would not be sufficient as the size of the COVID virus is 0.11 micron [3] The elimination of the return line may cause pressurization inside the building, but there are technical solutions as how to overcome the pressurization.

Certainly, there will be technical difficulties in closing the RAD like over pressurization or less comfortable temperature conditions, but these could be managed.

It should be noted, that the return line is nonexistent in the HVAC systems employed in the nuclear buildings, to avoid the spread of radioactive particles throughout the nuclear facility.

fortune-biomass-feedstock

Figure 1: Schematic of a single zone HVAC system. (Courtesy of General Physics Strategies, https://www.gpstrategies.com)

References

  1. McQuiston, F.C., Parker, J.D., and Spitler, D. “Heating, Ventilating and Air Conditioning Analysis and Design” 6th, Wiley (2005).
  2. Boston University Report, Website:http://www.bu.edu/cpo/files/2020/07/BU-HVAC-Guidance-7-28-20.pdf
  3. Rosaler, R.C. “ HVAC Handbook” McGraw-Hill (2004): 22.8.

Journal Statistics

Impact Factor: * 3.5

Acceptance Rate: 71.36%

Time to first decision: 10.4 days

Time from article received to acceptance: 2-3 weeks

Discover More: Recent Articles

Grant Support Articles

    Editor In Chief

    Masashi Emoto

  • Professor of Laboratory of Immunology
    Department of Laboratory Sciences
    Gunma University Graduate School of Health Sciences
    Gunma, Japan

© 2016-2025, Copyrights Fortune Journals. All Rights Reserved!